Accurate Thermoluminescence Dating - Calibration Down To The Last Ion

Thermoluminescence is used on sediment 'grains', which function as natural radiation dosimeters when buried with defects or impurities, to determine age. The valid range is 1,000 to 500,000 years and the technique is used extensively in archeology and earth sciences to date artifacts and rocks.

Thermoluminescence is used on sediment 'grains', which function as natural radiation dosimeters when buried with defects or impurities, to determine age. The valid range is 1,000 to 500,000 years and the technique is used extensively in archeology and earth sciences to date artifacts and rocks.

When exposed to radiation, quartz emits light proportional to the energy it absorbs. Replicating the very low dose of background radiation from natural sources present in quartz is a key precondition for precise and accurate dating results. Italian scientists have now developed a method to control the accuracy of the dose calibrations delivered to the samples during laboratory irradiation with heavy particles, replicating natural radiation exposure. Using oxygen and lithium ions from the Tandem accelerator at the National Institute of Nuclear Physics (INFN) in Florence, researchers found that their measurements were accurate to within 1%, despite large fluctuations in the irradiation beam.

In this study, the authors improve on previous calibration measurement techniques. To do so, they employ a pulsed ion beam that produces ion bunches, and rely on a system combining an aluminium foil and an electron detector, dubbed the MicroChannelPlate (MCP). When the ion bunches pass through the aluminium foil some electrons are emitted and detected by the MCP.

The MCP's energy resolution is not sufficient to count the number of ions constituting the bunch. However, Palla and colleagues have found they can perform the calibration by comparing the response of the MCP with that of a silicon detector, which offers extremely good energy resolution.

They show that it is possible to precisely evaluate the number of ions within each bunch crossing the foil and reaching the target to be irradiated.

Citation: L. Palla, C. Czelusniak, F. Taccetti, L. Carraresi, L. Castelli, M.E. Fedi, L. Giuntini, P. R. Maurenzig, L. Sottili, and N.Taccetti (2015), Accurate on line measurements of low fluences of charged particles, European Physical Journal Plus 130: 39, DOI 10.1140/epjp/i2015-15039-y

Old NID
154829
Categories

Latest reads

Article teaser image
Donald Trump does not have the power to rescind either constitutional amendments or federal laws by mere executive order, no matter how strongly he might wish otherwise. No president of the United…
Article teaser image
The Biden administration recently issued a new report showing causal links between alcohol and cancer, and it's about time. The link has been long-known, but alcohol carcinogenic properties have been…
Article teaser image
In British Iron Age society, land was inherited through the female line and husbands moved to live with the wife’s community. Strong women like Margaret Thatcher resulted.That was inferred due to DNA…